1.
Rev. colomb. anestesiol ; 44(1): 23-29, Jan.-Mar. 2016. ilus, tab
Article in English | LILACS, COLNAL | ID: lil-776306

ABSTRACT

Introduction: the bispectral index monitoring system (BIS) was introduced in the United States in 1994 and approved by the FDA in 1996 with the objective of measuring the level of consciousness through an algorithm analysis of the electroencephalogram (EEG) during general anesthesia. This novelty allowed both the surgeon and the anesthesiologist to have a more objective perception of anesthesia depth. The algorithm is based on different EEG parameters, including time, frequency, and spectral wave. This provides a non-dimensional number, which varies from zero to 100; with optimal levels being between 40 and 60. Objectives: Perform an analysis of the advantages and limitations of the anesthetic management with the bispectral index monitoring, specifically for the management and prevention of intraoperative awareness. Methodology: A non-systematic review was made from literature available in PubMed between the years 2001 and 2015, using keywords such as "BIS", "bispectral monitoring", "monitoreo cerebral", "despertar intraoperatorio", "recall" and "intraoperative awareness". Results: A total of 2526 articles were found, from which only the ones containing both bispectral monitoring and intraoperative awareness information were taken into consideration. A total of 68 articles were used for this review. Conclusion: BIS guided anesthesia has documented less immediate postoperative complications such as incidence of postoperative nausea/vomit, pain and delirium. It also prevents intraoperative awareness and its complications.


Introducción: El índice de monitoreo biespectral (BIS) fue introducido en Norte América en 1994 y aprobado por la FDA en 1996 con el objetivo de medir el nivel de conciencia realizando un análisis algorítmico del electroencefalograma (EEG) durante la anestesia general. Esta novedad permitió que tanto el cirujano como el anestesiólogo tuvieran una percepción más objetiva de la profundidad anestésica. El algoritmo está basado en diferentes parámetros del EEG, incluyendo tiempo, frecuencia y onda espectral. Esto provee un número no dimensional, que varía desde cero, hasta 100; siendo los niveles óptimos entre 40 y 60. Objetívos: Realizar un análisis de las ventajas y limitaciones del manejo anestésico con el monitor de análisis biespectral, específicamente en el manejo y prevención del despertar intraoperatorio. Metodología: Se realizó una revisión no sistemática de literatura disponible en PubMed entre los años 2001-2015, utilizando palabras clave como "BIS", "bispectral monitoring" "moni-toreo cerebral", "despertar intraoperatorio" "recall" y "intraoperative awareness". Resultados: Se encontraron un total de 2526 artículos, de los cuales solo se tomaron en cuenta aquellos que contenían información de tanto monitoria biespectral como despertar intraoperatorio. Un total de 68 artículos fueron utilizados para esta revisión. Conclusión: En la anestesia guiada por BIS se han documentado menores complicaciones postoperatorias inmediatas como la incidencia de nausea/vómito, dolor y delirium. Además de prevenir el despertar intraoperatorio y sus complicaciones.


Subject(s)
Humans
2.
Rev. colomb. anestesiol ; 43(supl.1): 9-14, Feb. 2015. ilus, tab
Article in English | LILACS, COLNAL | ID: lil-735058

ABSTRACT

Introduction: The way neurosurgery has evolved has led to increased emphasis on anaesthetic techniques aimed at improving patient well-being. In the United States alone, the number of neurosurgeries has increased significantly, with growth reflected in approximately 12,000 spine procedures per year and another 2700 different neurosurgical procedures per year. For anaesthetists, this means that they are faced more frequently with the need to select the most adequate neuroanaesthesia technique for each patient. Objectives: The purpose of this review is to analyze the role of inhaled and intravenous anaesthetics in neurosurgical procedures. Methodology: A search was conducted in PubMed using the terms TIVA, inhaled anaesthetics, neurosurgery and spine surgery. Results: The articles included in the review show that the adequate anaesthetic technique, besides ensuring a rapid onset of action, contributes to ease of titration with minimum effect on systemic and cerebral haemodynamics; it must enable intraoperative neurophysiological monitoring and rapid emergence, in order to allow early assessment of the patient’s neurological function and improved outcome. Conclusions: In recent years, the question regarding the use of inhaled vs. intravenous anaesthetics in neurosurgery has given rise to several research studies. Although TIVA is the technique used most frequently, inhaled anaesthetics have also been shown to be safe, titratable, and to provide for adequate intraoperative monitoring and cerebral haemodynamic stability. In patients with normal intracranial compliance, inhaled agents (IA) are a good alternative to TIVA, especially in places where hospital resources are limited.


Introducción: La evolución en neurocirugía ha fomentado las técnicas anestésicas en pro del bienestar del paciente. Solo en Estados Unidos el volumen de neurocirugías ha aumentado de forma significativa, mostrando un crecimiento aproximado de 12.000 procedimientos de columna al a ˜no, y de otros procedimientos neuroquirúrgicos de 2.700/a ˜no. Esto enfrenta con mayor frecuencia a los anestesiólogos a la elección de la técnica neuroanestésica adecuada para cada paciente. Objetivos: Esta revisión pretende realizar un análisis del rol de los anestésicos inhalados e intravenosos en procedimientos neuroquirúrgicos. Metodología: Se realizó una búsqueda en PubMed utilizando TIVA, anestésicos inhalados, neurocirugía y cirugía de columna como términos de búsqueda. Resultados: Los artículos revisados muestran que, la técnica anestésica adecuada, además de tener un rápido inicio de acción, ser fácilmente titulable, con mínimo efecto en la hemodinámia sistémica y cerebral; debe permitir monitorización neurofisiológica intraoperatoria, y un rápido despertar, con el fin de permitir una evaluación temprana de la función neurológica del paciente y mejorar su desenlace. Conclusiones: Durante los últimos a ˜nos la disyuntiva del uso de anestésicos inhalados ver sus intravenosos en neurocirugía ha producido el desarrollo de diversas investigaciones. Aunque TIVA es la técnica usada con mayor frecuencia, los anestésicos inhalados, también han mostrado ser seguros, titulables, proveer una adecuada monitorización intraoperatoria, y estabilidad hemodinámica cerebral. En pacientes con complacía intracraneal normal los agentes inhalados, son una buena alternativa a la anestesia con TIVA, especialmente en lugares con recursos hospitalarios limitados.


Subject(s)
Humans